Declared · report · attributed

Evidence reconciliation

Every pair preserves instrument, distance, statistic, source, and comparability status.

DeviceDeclaredReport / attributedStatus
Bestqool BQ60 95.6 mW/cm²
not stated · 7.62 cm · not stated
Source
55.33 mW/cm²
LLIA · BTS2048-VL-TEC · 30.48 cm · center
Source
context mismatch:distance bucket
Bestqool BQ60 95.6 mW/cm²
not stated · 7.62 cm · not stated
Source
95.6 mW/cm²
LLIA · BTS2048-VL-TEC · 7.62 cm · center
Source
comparability unknown:operating mode
Bestqool BQ60 95.6 mW/cm²
not stated · 7.62 cm · not stated
Source
64.61 mW/cm²
LLIA · BTS2048-VL-TEC · 15.24 cm · center
Source
context mismatch:distance bucket
Bestqool Pro100 90 mW/cm²
not stated · 15.24 cm · not stated
Source
51.7 mW/cm²
Light Therapy Insiders · OHSP-350-IRF · 15.24 cm · average
Source
comparability unknown:operating mode
Bestqool Pro100 90 mW/cm²
not stated · 15.24 cm · not stated
Source
65 mW/cm²
Light Therapy Insiders · OHSP-350-IRF · 15.24 cm · peak
Source
comparability unknown:operating mode
CurrentBody Skin LED Face Mask Series 2 30 mW/cm²
not stated · distance not stated · not stated
Source
18.5 mW/cm²
Light Therapy Insiders · OHSP-350-IRF · 0 cm · average
Source
comparability unknown:distance
HigherDOSE Red Light Face Mask 50 mW/cm²
not stated · distance not stated · not stated
Source
26 mW/cm²
Light Therapy Insiders · OHSP-350-IRF · 0 cm · average
Source
comparability unknown:distance
Hooga Ultra 1500 165 mW/cm²
not stated · 15.24 cm · not stated
Source
81.7 mW/cm²
Light Therapy Insiders · OHSP-350-IRF · 15.24 cm · average
Source
comparability unknown:operating mode
Hooga Ultra 1500 165 mW/cm²
not stated · 15.24 cm · not stated
Source
104 mW/cm²
Light Therapy Insiders · OHSP-350-IRF · 15.24 cm · peak
Source
comparability unknown:operating mode
Hooga Ultra 360 132 mW/cm²
not stated · 15.24 cm · not stated
Source
74 mW/cm²
Light Therapy Insiders · OHSP-350-IRF · 15.24 cm · peak
Source
comparability unknown:operating mode
Hooga Ultra 360 132 mW/cm²
not stated · 15.24 cm · not stated
Source
60 mW/cm²
Light Therapy Insiders · OHSP-350-IRF · 15.24 cm · average
Source
comparability unknown:operating mode
Mito Red Light MitoADAPT MIN 4.0 125 mW/cm²
solar meter · 15.24 cm · peak
Source
40.7 mW/cm²
LLIA · spectroradiometer · 15.24 cm · average
Source
context mismatch:spatial statistic
Mito Red Light MitoADAPT MIN 4.0 125 mW/cm²
solar meter · 15.24 cm · peak
Source
56.4 mW/cm²
LLIA · spectroradiometer · 15.24 cm · peak
Source
comparable: gap 54.9%
Mito Red Light MitoPRO 1500+ 68 mW/cm²
spectroradiometer · 15.24 cm · peak
Source
68.2 mW/cm²
LLIA · spectroradiometer · 15.24 cm · peak
Source
comparable: gap -0.3%
Mito Red Light MitoPRO 1500+ 68 mW/cm²
spectroradiometer · 15.24 cm · peak
Source
56.8 mW/cm²
LLIA · spectroradiometer · 15.24 cm · average
Source
context mismatch:spatial statistic
Mito Red Light MitoPRO 1500X 160 mW/cm²
solar meter · 15.24 cm · peak
Source
53.5 mW/cm²
LLIA · spectroradiometer · 15.24 cm · average
Source
context mismatch:spatial statistic
Mito Red Light MitoPRO 1500X 160 mW/cm²
solar meter · 15.24 cm · peak
Source
72.5 mW/cm²
LLIA · spectroradiometer · 15.24 cm · peak
Source
comparable: gap 54.7%
Mito Red Light MitoPRO 300+ 60 mW/cm²
spectroradiometer · 15.24 cm · peak
Source
60.1 mW/cm²
LLIA · spectroradiometer · 15.24 cm · peak
Source
comparable: gap -0.2%
Mito Red Light MitoPRO 300+ 60 mW/cm²
spectroradiometer · 15.24 cm · peak
Source
41.8 mW/cm²
LLIA · spectroradiometer · 15.24 cm · average
Source
context mismatch:spatial statistic
Mito Red Light MitoPRO 300X 130 mW/cm²
solar meter · 15.24 cm · peak
Source
55.9 mW/cm²
LLIA · spectroradiometer · 15.24 cm · peak
Source
comparable: gap 57.0%
Mito Red Light MitoPRO 300X 130 mW/cm²
solar meter · 15.24 cm · peak
Source
38.2 mW/cm²
LLIA · spectroradiometer · 15.24 cm · average
Source
context mismatch:spatial statistic
Omnilux Contour Face 30 mW/cm²
not stated · distance not stated · not stated
Source
26.7 mW/cm²
Light Therapy Insiders · OHSP-350-IRF · 0 cm · average
Source
comparability unknown:distance
PlatinumLED BioMax Pro Ultra 292 mW/cm²
not stated · 15.24 cm · peak
Source
120 mW/cm²
Light Therapy Insiders · OHSP-350-IRF · 15.24 cm · peak
Source
comparability unknown:operating mode
Shark CryoGlow FW312 128 mW/cm²
not stated · distance not stated · not stated
Source
1.9 mW/cm²
Ben Rawlings · Jeti Specbos 2501 · 1.6 cm · point
Source
comparability unknown:distance
Shark CryoGlow FW312 128 mW/cm²
not stated · distance not stated · not stated
Source
2.1 mW/cm²
Ben Rawlings · Jeti Specbos 2501 · 1.6 cm · point
Source
comparability unknown:distance
Shark CryoGlow FW312 128 mW/cm²
not stated · distance not stated · not stated
Source
2.18 mW/cm²
Ben Rawlings · Jeti Specbos 2501 · 1.6 cm · point
Source
comparability unknown:distance
Reconciliation queue

Fields blocking comparison

RSS feed
Bestqool BQ60

context mismatch:distance bucket

Bestqool BQ60

comparability unknown:operating mode

Bestqool BQ60

context mismatch:distance bucket

Bestqool Pro100

comparability unknown:operating mode

Bestqool Pro100

comparability unknown:operating mode

CurrentBody Skin LED Face Mask Series 2

comparability unknown:distance

HigherDOSE Red Light Face Mask

comparability unknown:distance

Hooga Ultra 1500

comparability unknown:operating mode

Hooga Ultra 1500

comparability unknown:operating mode

Hooga Ultra 360

comparability unknown:operating mode

Hooga Ultra 360

comparability unknown:operating mode

Mito Red Light MitoADAPT MIN 4.0

context mismatch:spatial statistic