Documentary difference · published immediately

Mito Red Light MitoPRO 1500X

Source A reports one number and source B reports another under different or incompletely stated contexts. No adverse interpretation or cross-distance normalization is applied.

Comparability status

comparable context: declared–measured gap 54.7%

averaginginstrumentdeclared vs measured
Evidence

Number passports

Full reconciliation
160 mW/cm2 C2 · declared instrument and distance
Claim ID
rli:mito-red-light:mitopro-1500x:irradiance-declared:mitoredlight-com-92e549:r1
Technique
solar_meter · 15.24 cm · peak
Band
red nir combined
Geometry
peak in device footprint
Evidence class
C2
Measurement event
not applicable
“>160 mW/cm2” source quotation
53.5 mW/cm2 Ls · vendor report summary; PDF not reviewed
Claim ID
rli:mito-red-light:mitopro-1500x:irradiance-report-average:mitoredlight-com-8c5984:r1
Technique
spectroradiometer · 15.24 cm · average
Band
red nir combined
Geometry
area below leds
Evidence class
Ls
Measurement event
event-188f73109394a3
“Average Irradiance @ 6in | 53.5 mW/cm2” source quotation
72.5 mW/cm2 Ls · vendor report summary; PDF not reviewed
Claim ID
rli:mito-red-light:mitopro-1500x:irradiance-report-peak:mitoredlight-com-8c5984:r1
Technique
spectroradiometer · 15.24 cm · peak
Band
red nir combined
Geometry
peak in device footprint
Evidence class
Ls
Measurement event
event-188f73109394a3
“Peak Irradiance @ 6in | 72.5 mW/cm2” source quotation